The Digi-Mag® Series DM-1000
Digital Differential Pressure and Flow Gages monitor the pressure of air and compatible gases just as its famous analog predecessor the Magnehelic® DifferentialPressure Gage. All models are factory calibrated to specific ranges as listed in the chart below. The 4-digit LCD can display readings in common English and metric units so conversions are not necessary. The simplified four button operation reduces set up time and simplifies calibration with its digital push
button zero and span.
The DigiMag® Digital Gages are more versatile than analog gages with their ability to be field-programmed to select pressure, air
velocity or flow operation depending on model.
The DigiMag® Digital Gages have an added feature for filter applications where a set point can be input where the display will blink when
the filter is dirty, alerting the user that a maintenance action needs to occur.
Programming the Series DM-1000 is easy using the menu key to access 4 simplified menus which provide access to
depending on model: Security level; engineering units; K-factor for use with various Pitot tubes and flow sensors, circular or rectangular duct size for volumetric flow operation; filter set point; view peak and valley process readings; digital damping for smoothing erratic process applications; display update to conserve battery life; zero and span field calibration.
The Series DM-1000 DigiMag® Digital Differential Pressure and Air Flow Gages possess a full-scale accuracy of 1% on ranges down to 2? w.c. and 2% accuracy down to the very low ranges of 1? to 0.25? w.c. DigiMag® Digital Differential Pressure Gages offer power
versatility by working with 9-24 VDC line power or simply 9V battery power. If using line power and connecting the 9V battery, the battery will act as a
back-up if line power is lost or interrupted.
SPECIFICATIONS
Service: Air and non-combustible, compatible gases.
Wetted
Materials: Consult factory.
Housing
Materials: Glass filled plastic.
Accuracy: ±1% F.S.
including linearity, hysteresis and repeatability; ±2% F.S. for ranges 1 in
w.c. and below.
Temperature
Limits: 0 to 140°F (-18 to 60°C).
Compensated
Temperature Limits: 32 to 122°F (0 to 50°C).
Long Term
Stability: ±1% F.S. per year.
Thermal
Effect: ±0.05% F.S./°F typ.; ±0.10% F.S./°F for ranges 1 in w.c. and below.
Display: 4-digit LCD
(digits: 0.60?H x 0.33?W).
Display
Update: Selectable for 1 second to 10 minutes or update only from button push.
Pressure
Limits: Normal and bi-directional ranges 5? w.c. and lower = 2 psi (13.7 kPa); Normal
and bi-directional ranges 10? w.c. and higher = 11 psi (75 KPa).
Selectable
Engineering Units: in w.c., psi, kPa, Pa, mm w.c., mBar, in Hg, mm Hg, FS
(0-100%).
Power
Requirements: 9V battery or external power supply 9-24 VDC. Battery included but
not connected.
Type of
Battery: 9V alkaline battery (Duracell® PC 1604 or equivalent).
Battery
Service Life: Battery life depending on the display update setting: 150 hours
(typical) if display update = 1 second; 9 month (typical) if display update = 10 minutes;
1.5 years (typical) if display update is disabled. Battery may last up to four
times longer when using lithium-based battery ULTRALIFE U9VL-J.
Current
Consumption: 5 mA maximum.
Electrical
Connections: Removable terminal block for 16 to 26 AWG.
Electrical
Entry: Cable gland for 0.114 to 0.250? (2.9 to 6.4 mm) diameter cable.
Process
Connections: 1/8? (3 mm) I.D. tubing.
Enclosure
Rating: NEMA 4X (IP66).
Weight: 1.18 lb (535
g).
Size: 5? (127 mm)
O.D. front face.
Agency Approvals: CE.
ACCESSORIES nad OPTIONS:
- A-299 - Mounting
bracket, flush mount Magnehelic® gage in bracket. Bracket is then
surface mounted. Steel with gray hammertone epoxy finish.
- A-300 - Flat aluminum bracket for flush mounting Magnehelic® gage.
- A-286 - Front flange for panel mounting Magnehelic® gage.
- A-310A - 3-way vent valve, plastic, 1/8" NPT to 1/4" metal tubing, 80 psi rating, replaces former Model A-310 (brass).
- A-480 - Plastic static pressure tip.
- A-481 - Installer kit includes two static tips and 7 ft (2.1 m) of PVC tubing.
- DM-1200 - Airflow and velocity option. Gage reports airflow in scfm and m3/hr and velocity in fpm and mps.
Order accessories and options below
Units of measure and ranges by model
|
|
Model
|
In w.c.
|
psi
|
kPa
|
Pa
|
mbar
|
mm
|
In Hg
|
Mm Hg
|
% of FS
|
Resol. in w.c.
|
|
|
DM-1102
DM-1103
DM-1104
DM-1105
DM-1107
DM-1108
DM-1109
DM-1110
DM-1111
DM-1112
|
0.250
0.500
1.000
2.000
5.000
10.00
15.00
25.00
50.00
100.0
|
–
–
–
–
0.181
0.361
0.543
0.903
1.806
3.613
|
0.062
0.124
0.249
0.498
1.245
2.491
3.738
6.227
12.45
24.91
|
62.20
124.5
249.1
498.2
1245
2491
3738
6227
–
–
|
0.622
1.245
2.492
4.982
12.45
24.91
37.38
62.27
124.5
249.1
|
6.35
12.70
25.40
50.80
127.0
254.0
381.0
635.0
1270
2540
|
–
–
–
–
0.368
0.736
1.104
1.839
3.678
7.355
|
0.467
0.934
1.868
3.736
9.34
18.68
28.02
46.71
93.42
186.8
|
100.0
100.0
100.0
100.0
100.0
100.0
100.0
100.0
100.0
100.0
|
0.001
0.001
0.001
0.001
0.002
0.010
|