Internal Motor Sensor
AC Magnetic Field Threshold: > 40 mGauss at 60 Hz
External Input
External
Contact Input: Electronic
solid state switch closure or logic driven voltage output
Range: 0 to 3
V DC (USB powered), 0 to 2.5 V DC (battery powered)
Maximum
State and Runtime Frequency: 1 Hz
Solid
State Switch Closure: Input
Low: < 10 KΩ; Input High: > 500 KΩ
Internal
Weak Pull-Up: 100
KΩ
Input
Impedance: Solid
state switch closure: 100 KΩ pull up
Logger
Resolution: Pulse: 1 pulse, Runtime: 1 second, State and Event: 1 State or Event
Time
Accuracy: ±1
minute per month at 25°C (77°F)
Battery
Life: 1
year, typical with logging intervals greater than 1 minute and normally open
contacts
Memory:
UX90-004:
128 KB (84,650 measurements, maximum)
UX90-004M: 512 KB (346,795 measurements, maximum)
Download
Type: USB
2.0 interface
Download
Time: 10
seconds for 128 KB; 30 seconds for 512 KB
Logger
Operating Range:
Logging:
-20° to 70°C (-4° to 158°F); 0 to 95% RH (non-condensing)
Launch/Readout: 0° to 50°C (32° to 122°F) per USB specification
LCD: LCD
is visible from: 0° to 50°C (32° to 122°F); the LCD may react slowly or go
blank in temperatures outside this range
Size: 3.66 x 8.48 x 1.52 cm (1.44 x 3.34 x 0.6 in.)
Weight: 30 g (1.06 oz)
Environmental
Rating: IP50
The
CE Marking identifies this product as complying with all relevant directives in
the European Union (EU)