External event input
Event sensor: Two-wire interface suitable for measuring mechanical and electrical contact closures
Maximum input frequency: 1 Hz (1 pulse per second)
Lockout time: 500 ms
Minimum pulse width: 1 ms (hardware debounce)
Input/output impedance: 100 kΩ
Edge detection: Falling edge, contact closure, or Schmitt-trigger buffer
Preferred switch type: Normally open. For maximum battery life, the
event input should be used with its preferred switch type. The logger
will work with normally closed switches, but battery life will be
compromised.
Open circuit input voltage: Battery voltage; nominally 3.0 V
Maximum input voltage: Battery voltage + 0.3 V
User connection: 24 AWG, 2 leads: white (+), black (-)
Temperature measurement
Measurement range: -20° to 70°C (-4° to 158°F)
Accuracy: ± 0.53°C from 0° to 50°C (± 0.95°F from 32° to 122°F). A solar radiation shield is required for accurate temperature
measurements in sunlight.
Resolution: 0.14°C at 25°C (0.25°F at 77°F)
Drift: Less than 0.1°C/year (0.2°F/year)
Response time: Airflow of 2 m/s (4.4 mph): 10 minutes, typical to 90%
Logger
Time accuracy: ± 1 minute per month at 25°C (77°F)
Operating range: -20° to 70°C (-4° to 158°F)
Environmental rating: Tested to NEMA 6 and IP67; suitable for deployment outdoors
Drop specification: 1.5 m (5 ft) onto concrete
NIST traceable certification: Available for temperature only at additional charge; temperature range -20° to 70°C (-4° to 158°F)
Battery: CR-2032 3V lithium battery; 1 year typical use
Memory: 64K bytes
Materials: Polypropylene case; stainless steel screws; Buna-N o-ring; PVC cable insulation
Weight: 50 g (1.7 oz.)
Dimensions: 71 x 33 x 23 mm (2.8 x 1.3 x 0.9 inches); 1.8 m (6 ft) cable
The CE Marking identifies this product as complying with the relevant directives in the European Union (EU).